43B Power Quality Analyzer Features
One and three phase power on
balanced loads
Watts, power factor, COS ?, VA and VAR
Voltage and current waveforms
Voltage, current, and power harmonics
Up to 51st harmonic
Total harmonic distortion (THD)
Phase angle of individual harmonics
Fluke 43B Power Analyser Specifications
Menu items Measurements Ranges Accuracy
Volts/Amps/Hz Volts 5.000 V-1250 V
Amps 50.00A-50.00 kA +/- (1%+10)
Mains frequency 40.0 - 70.0 Hz +/- (0.5%+2)
CF Crest Factor 1.0 to 10.0 +/- (5%+1)
Power Watts, VAR, VA 250 W-1.56 GW +/- (4%+4)
PF, DPF, COS ? 0.25-0.9 +/- 0.04
0.90-1.00 +/- 0.03
Harmonics Volts 1st to 51st harmonic +/- (3%+2) to +/- (15%+5)
Amps 1st to 51st +/- (3%+8) to +/- (15%+8)
Watts 1st to 51st +/- (5%+2) to +/- (30%+5)
K-factor 1.0 to 30.0 +/- 10%
Sags & Swells Voltage and Current 4 min-16 days +/- (2%+10)
selectable
Transient Capture 40 ns pulse width Select 20/50/100/200% +/- 5% of full scale
Up to 40 transients above or below line
voltage
Inrush Current 1sec. to 5 min selectable 1 A to 1000 A +/- 5% of full scale
Ohms/Continuity/ Ohms 500.0 O to 30.00 MO +/- (0.6%+5)
Capacitance Capacitance 50.00 nF to 500.0 µF +/- (2%+10)
Temperature C -100.0°C to 400.0C +/- (0.5%+5)
(with accessory) F -200.0F to 800.0F
Scope DC, AC, AC+DC, peak, Sampling rate: 25 MS/sec
peak-peak, Hz, duty cycle, Bandwidth:
phase, pulse width, Voltage BW (Channel 1) 20 MHz
crest factor Current BW (Channel 2) 15 kHz
Screen saves All functions 20 screens
Recording V/A/Hz, Power, Harmonics, 4 min to 16 days Select any two O/Cap, Temperature, Scope selectable parameters in each display mode.
Weekly Hire Cost: £100.00