FTN01 FIELD THERMAL NEEDLE SYSTEM

Weekly Hire Cost From: £325.00


Enquire Now
 
Overview

Overview

The FTN01 Field Thermal Needle System allows for performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. It is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements.

The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held control and readout unit CRU01. The measurement method is based on the so-called NSSP technique, which uses a probe in which both a heating wire and a temperature sensor are incorporated. The probe is inserted into the soil and from the response to a heating step, the thermal resistivity of the soil can be calculated. The main application of FTN is route surveying for high voltage electric power cables and for heated pipelines.

Suitability for field surveys:

The FTN01's is able to perform measurements without external power source and the system is sufficiently robust to survive manual insertion into most common soils. The system runs as a standalone unit, powered by the batteries in the CRU. Recharging can be done by a 12VDC source or a car battery using the CA01 car adapter, or on 220/110 VAC using the WSA01 wall socket adapter.

Saving time:

Many cables and pipelines are buried at a depth of around 1.5m. The long lance, LN01, 1.5m, serves to The latest software algorithms perform numerous plausibility checks and thus ensure that the system is not only easy to use, but also the maximum reliability of the measured results. The transmitter contains a capacitor that is charged and then discharged into the target cable. During this process the test sample must be connected in such a way that current can flow through it. The flexible coupler is used to couple to the current pulse in the target cable; the direction of flow of the current pulse and its amplitude are indicated on the display of the receiver. The amplitude of the current pulse is dependent on the loop resistance. To be able to clearly determine the direction of current flow, the positive output is colour-coded red and the flexible coupler marked with an arrow. avoid the necessity to dig a large access hole. In general a small-diameter hole is drilled to a depth just above the required depth of measurement. After this the lance LN01 is inserted. The probe TP09 itself (17cm long at the tip of LN01) is then hammered down into the undisturbed soil.

Automatic processing:

CRU01 automatically processes the measurement data and gives both an end-result and a quality indication of the measurement. CRU01 can archive 30 measurements. In case of review, the end result is preferably checked and recalculated by analysis of the measured data in a spreadsheet (like EXCEL) or a mathematical program.

Local calibration:

Verification of the stability of the total system can be done by repeated testing in glycerol. This test can also be performed in the field.